Skip to content

Wideband Covariance Magnetometry below the Diffraction Limit

MetadataDetails
Publication Date2025-09-25
JournalPhysical Review Letters
AuthorsXuan Hoang Le, Pavel E. Dolgirev, Piotr Put, Emilee Anne Peterson, Arjun Pillai
InstitutionsHarvard University, ETH Zurich
AnalysisFull AI Review Included

Technical Documentation & Analysis: Wideband Covariance Magnetometry

Section titled “Technical Documentation & Analysis: Wideband Covariance Magnetometry”

This document analyzes the research paper “Wideband covariance magnetometry below the diffraction limit” to provide technical specifications and align the material requirements with 6CCVD’s advanced MPCVD diamond capabilities, focusing on applications in quantum sensing and condensed matter physics.


The research successfully demonstrates a novel technique for nanoscale, wideband magnetic correlation sensing using Nitrogen-Vacancy (NV) centers in diamond.

  • Core Achievement: Measurement of two-point spatio-temporal magnetic correlations across a broad spectrum (DC to GHz) with spatial resolution below the optical diffraction limit.
  • Material Requirement: The technique relies on electronic-grade, isotopically enriched Single Crystal Diamond (SCD) to ensure long spin coherence times (T2 > 1 ms).
  • High Sensitivity: Achieved a magnetic sensitivity of 15 nT Hz-1/4 for correlated MHz-range noise, corresponding to a detectable noise strength of 4 nT2/Hz in 40 minutes.
  • Advanced Readout: Utilizes a Resonantly-Assisted Spin-to-Charge Conversion (RA-SCC) protocol, yielding low readout noise (σR = 3-4) essential for high-fidelity correlation measurements.
  • Wideband Capability: Extends NV magnetometry to the GHz regime using correlated T1 spectroscopy, enabling the study of high-frequency dynamics like superradiance and critical fluctuations in 2D materials.
  • Fabrication Integration: Requires precise fabrication of on-diamond microwave (MW) delivery structures (Ti/Au striplines) for independent NV control.

The following hard data points were extracted from the experimental setup and performance metrics:

ParameterValueUnitContext
Diamond Material GradeElectronic Grade CVDN/AIsotopically enriched in 12C
NV Implantation Dose1011cm-214N ions at 25 keV
NV Center Depth~50 ± 20nmShallow implantation for surface sensing
Spin Coherence Time (T2)> 1msMeasured via Hahn-echo experiment
Magnetic Sensitivity (MHz)15nT Hz-1/4For correlated T2 spectroscopy
Detectable Noise Strength4nT2/HzTotal experiment time 40 minutes
Frequency Band ProbedDC to GHzN/AVia correlated T2 and T1 spectroscopy
Readout Noise (σR)3-4N/AAchieved using RA-SCC protocol
Metalization Stack225 nm Au / 10 nm TiN/AStripline fabrication on diamond
Operating Temperature11KCryostat conditions

The experiment relies on precise material engineering and complex quantum control protocols:

  1. Diamond Substrate: Electronic grade CVD diamond, isotopically enriched in 12C to minimize coupling to spurious nuclear spins and maximize T2 coherence.
  2. NV Creation: 14N ion implantation (25 keV, 1011 cm-2 dose) followed by a two-step vacuum annealing process (800°C then 1200°C) to form shallow NV centers (~50 nm depth).
  3. Surface Preparation: Triacid cleaning (sulfuric:nitric:perchloric acid) to remove graphitic carbon and ensure a clean surface for optical access and metalization.
  4. Microwave (MW) Delivery: Photolithographically defined stripline (225 nm Au on 10 nm Ti adhesive layer) fabricated directly onto the diamond surface, forming an omega-loop structure for localized MW field delivery.
  5. Optical Setup: Single-path scanning confocal microscope integrated with a cryostat (11 K) for high-resolution imaging and control.
  6. High-Fidelity Readout (RA-SCC): Utilizes three lasers (532 nm, 637 nm, 660 nm) to perform resonant excitation and spin-to-charge conversion, enabling sequential, independent, low-noise readout of two spectrally resolved NV centers.
  7. Sensing Protocols:
    • Correlated T2: Uses Ramsey and XY8-N sequences to probe MHz-range noise correlations.
    • Correlated T1: Uses amplitude-modulated Gaussian noise to probe correlated few-GHz noise, observing superradiant-like dynamics.

This research highlights the critical need for ultra-high-quality diamond materials and precision fabrication, areas where 6CCVD provides industry-leading solutions.

The success of wideband covariance magnetometry hinges on maximizing the NV spin coherence time (T2).

  • Isotopically Enriched Single Crystal Diamond (SCD): 6CCVD supplies electronic-grade SCD wafers with < 100 ppm 13C enrichment. This low concentration of nuclear spins is essential to minimize decoherence and achieve the long T2 times (> 1 ms) required for sensitive quantum sensing protocols like those demonstrated in the paper.
  • High Purity Substrates: We ensure extremely low native nitrogen concentration (P1 centers) in our SCD, minimizing magnetic noise and inhomogeneous broadening, which is crucial for resolving individual NV optical transitions at cryogenic temperatures (11 K).

Replicating and extending this research requires precise control over NV environment and integration of complex RF structures.

Research Requirement6CCVD CapabilityTechnical Advantage
Shallow NV CreationSCD substrates polished to Ra < 1 nmUltra-smooth surfaces minimize surface-related noise and maximize photon collection efficiency for shallow NV centers (~50 nm depth).
On-Chip MW DeliveryInternal Metalization ServicesWe offer custom deposition of the required Ti/Au stack, as well as Pt, Pd, W, and Cu. This allows researchers to integrate optimized striplines, coplanar waveguides, or omega-loops directly onto the diamond surface.
Scalability & ArraysCustom dimensions up to 125 mm (PCD) and large SCD platesSupports scaling the technique to multi-NV clusters, scanning-NV platforms, or nanopillar arrays for higher-order correlation measurements.
Thickness ControlSCD thickness from 0.1 ”m to 500 ”mProvides flexibility for optimizing heat dissipation in high-power MW experiments or integrating thin films onto the diamond.

6CCVD is more than a material supplier; we are a technical partner in quantum research.

  • NV Optimization Consultation: 6CCVD’s in-house PhD team can assist with material selection, surface termination (e.g., oxygen or hydrogen termination), and advising on post-growth processing parameters (like the 800°C/1200°C annealing protocol used here) required for optimizing NV creation yield and maximizing coherence times for similar Quantum Sensing and Wideband Magnetometry projects.
  • Global Logistics: We offer reliable global shipping (DDU default, DDP available) to ensure sensitive, custom-fabricated diamond components reach your lab efficiently and safely, supporting international collaboration.

For custom specifications or material consultation, visit 6ccvd.com or contact our engineering team directly.

View Original Abstract

We experimentally demonstrate a method for measuring correlations of wideband magnetic signals with spatial resolution below the optical diffraction limit. Our technique employs two nitrogen-vacancy (NV) centers in diamond as nanoscale magnetometers, spectrally resolved by inhomogeneous optical transitions. Using high-fidelity optical readout and long spin coherence time, we probe correlated megahertz-range noise with sensitivity of 15 nTHz^{-1/4}. In addition, we use this system for correlated T_{1} relaxometry, enabling correlation measurements of gigahertz-range noise. Under such externally applied noise, while individual NV centers exhibit featureless relaxation, their correlation displays rich coherent and incoherent dynamics reminiscent of superradiance physics. This capability to probe high-frequency correlations provides a powerful tool for investigating a variety of condensed-matter phenomena characterized by nonlocal correlations.

  1. 1997 - Quantum Optics [Crossref]
  2. 2004 - Introduction to Superconductivity