Skip to content

Sensing Electrochemical Signals Using a Nitrogen-Vacancy Center in Diamond

MetadataDetails
Publication Date2021-02-01
JournalNanomaterials
AuthorsHossein T. Dinani, Enrique Muñoz, Jeronimo R. Maze
InstitutionsUniversidad Mayor, Pontificia Universidad CatĂłlica de Chile
Citations5
AnalysisFull AI Review Included

Technical Documentation & Analysis: NV Center Electrochemical Sensing

Section titled “Technical Documentation & Analysis: NV Center Electrochemical Sensing”

This document analyzes the research paper “Sensing Electrochemical Signals Using a Nitrogen-Vacancy Center in Diamond” to highlight the material requirements and propose specific solutions available through 6CCVD’s advanced MPCVD diamond catalog.


The research proposes a highly sensitive, robust method for monitoring ionic concentration in electrolyte solutions using the electron spin of a Nitrogen-Vacancy (NV) center in bulk diamond.

  • Core Value Proposition: Diamond NV centers act as nanoscale electrochemical sensors, leveraging their long spin coherence time and resilience to extreme chemical environments.
  • Sensing Mechanism: Ionic diffusion fluctuations in the electrolyte generate electric field noise, which is detected by measuring the resulting inhomogeneous dephasing rate ($1/T_{2}^{*}$) of the NV electron spin.
  • High Sensitivity Demonstrated: The induced dephasing rate ($1/T_{2}^{*}$) exceeds 10 kHz for bulk concentrations ($c_{b}$) greater than 0.04 mol/m$^{3}$, and surpasses 300 kHz for $c_{b} > 100$ mol/m$^{3}$.
  • Low Concentration Sensing: For $c_{b} < 0.1$ mol/m$^{3}$, the concentration can be estimated by resolving the electric field gradient (Stark effect) induced at the NV position.
  • Material Requirement: Successful implementation requires high-purity, bulk Single Crystal Diamond (SCD) with an ultra-smooth surface for precise, shallow NV implantation (e.g., 10 nm depth).
  • 6CCVD Relevance: This work validates the need for high-quality SCD substrates and custom surface engineering, core specialties of 6CCVD, to advance quantum sensing applications in chemistry and industry.

The following hard data points were extracted from the theoretical analysis and simulation parameters:

ParameterValueUnitContext
Sensing Mechanism$1/T_{2}^{*}$ (Dephasing Rate)HzInduced by electric field fluctuations from ion diffusion.
NV Center Depth ($z$)10nmPosition of the NV center from the diamond surface ($z=0$).
Maximum Implantation Depth ($d_{max}$)14nmMaximum depth used for implanted nitrogen ions.
Areal Density of Implanted N ($D_{s}$)$10^{12}$cm$^{-2}$Used for calculating volume density of N$_{s}$ and NV defects.
High Concentration Threshold ($c_{b}$)&gt; 100mol/m$^{3}$Induced $1/T_{2}^{*}$ &gt; 300 kHz.
Mid Concentration Threshold ($c_{b}$)&gt; 0.04mol/m$^{3}$Induced $1/T_{2}^{*}$ &gt; 10 kHz.
Low Concentration Range ($c_{b}$)&lt; 0.1mol/m$^{3}$Sensing achieved via Electric Field Gradient (Stark Effect).
Sensitivity ($\eta$) Example3.27mol m$^{-3}$ Hz$^{-1/2}$Calculated at $c_{b} = 10$ mol/m$^{3}$ and $T_{2}^{*} \approx 10$ ”s.
Operating Temperature (T)298KRoom temperature operation assumed.
Zero Field Splitting (D)2.87GHzGround state spin triplet splitting of the NV center.
Electric Field Coupling ($d_{\parallel}$)0.35Hz cm/VCoupling parameter for the $H_{E0}$ term.
Electric Field Coupling ($d_{\perp}$)17Hz cm/VCoupling parameter for the $H_{E1}$ term.

The theoretical framework relies on coupling classical fluid dynamics and electrostatics with quantum spin dynamics:

  1. Electrolyte Modeling: The Nernst-Planck equation was used to model the flux ($N_{s}$) of ionic species (e.g., $\text{Cu}^{2+}$/$\text{SO}_{4}^{2-}$) in the liquid electrolyte, accounting for concentration gradients and electric field effects.
  2. Electrostatic Solution: The Poisson equation was solved numerically to determine the electric potential ($\phi$) and electric field (E) profiles inside the electrolyte and the diamond, considering the dielectric response and ionization of defects within the diamond.
  3. Fluctuation Correlation: Statistical analysis was performed to derive the correlation function of the electric field fluctuations ($\delta E$) at the diamond surface ($z=0^{+}$), which are directly proportional to the bulk ion concentration ($c_{b}$).
  4. NV Spin Dynamics: The NV center ground state Hamiltonian was used, incorporating the electric field terms ($H_{E0}, H_{E1}, H_{E2}$) responsible for the Stark effect and sensitivity to electric field noise.
  5. Dephasing Rate Calculation: The inhomogeneous dephasing rate ($1/T_{2}^{*}$) was calculated from the variance of the accumulated phase ($\langle \delta \psi^{2} \rangle$), showing a $t^{2}$ scaling in the free induction decay signal.
  6. Sensing Protocol Simulation: The sensitivity ($\eta$) was derived based on a simulated Ramsey measurement sequence ($\pi/2 - \tau - \pi/2$ pulses) used to estimate $T_{2}^{*}$ and, subsequently, the ion concentration $c_{b}$.

This research demonstrates the critical need for high-quality, customized diamond materials to realize advanced quantum sensors. 6CCVD is uniquely positioned to supply the necessary substrates and engineering services to replicate and extend this work into practical devices.

To achieve the long intrinsic coherence times ($T_{2}^{}$) required to resolve the small electrochemical signals (where the induced $1/T_{2}^{}$ must be larger than the intrinsic noise), the highest purity material is essential.

Application Requirement6CCVD Material RecommendationRationale & Advantage
High-Purity SubstrateOptical Grade Single Crystal Diamond (SCD)Provides extremely low intrinsic nitrogen and low $^{13}\text{C}$ content, maximizing the intrinsic $T_{2}^{*}$ coherence time and ensuring the sensor is dominated by external electrochemical noise, not internal material defects.
Electrochemical ElectrodeHeavy Boron Doped Diamond (BDD)While the paper focuses on NV, BDD is the superior material for the electrode interface itself, offering unparalleled chemical inertness, stability, and a wide electrochemical window for process control applications.

The paper highlights the need for precise NV placement (10 nm depth) and suggests integration with photonic structures for enhanced sensitivity. 6CCVD offers comprehensive customization services to meet these advanced engineering requirements:

  • Custom Dimensions and Thickness: We supply SCD plates and wafers in custom dimensions, with thicknesses ranging from 0.1 ”m up to 500 ”m, and substrates up to 10 mm, suitable for bulk or thin-film integration.
  • Ultra-Smooth Polishing: Achieving reliable contact with the electrolyte and ensuring precise shallow implantation requires exceptional surface quality. 6CCVD guarantees Ra &lt; 1 nm polishing on SCD, minimizing surface defects that can degrade NV coherence.
  • Integrated Metalization: The Ramsey measurement sequence requires microwave (MW) structures (e.g., coplanar waveguides) near the NV center. We offer in-house custom metalization using materials including Au, Pt, Pd, Ti, W, and Cu, enabling direct integration of control electronics onto the diamond substrate.
  • Large-Scale Arrays: For scaling up sensor technology, 6CCVD provides Polycrystalline Diamond (PCD) wafers up to 125 mm in diameter, polished to Ra &lt; 5 nm, suitable for large-area sensor arrays.

6CCVD’s in-house PhD team specializes in MPCVD growth optimization and material selection for quantum and electrochemical applications. We can assist researchers and engineers in:

  • Selecting the optimal SCD grade and thickness for subsequent shallow NV implantation protocols.
  • Designing custom metalization layouts for efficient MW delivery and electric field generation necessary for Ramsey spectroscopy and Stark effect sensing.
  • Consulting on material integration for similar ionic concentration monitoring and pH sensing projects.

For custom specifications or material consultation, visit 6ccvd.com or contact our engineering team directly.

View Original Abstract

Chemical sensors with high sensitivity that can be used under extreme conditions and can be miniaturized are of high interest in science and industry. The nitrogen-vacancy (NV) center in diamond is an ideal candidate as a nanosensor due to the long coherence time of its electron spin and its optical accessibility. In this theoretical work, we propose the use of an NV center to detect electrochemical signals emerging from an electrolyte solution, thus obtaining a concentration sensor. For this purpose, we propose the use of the inhomogeneous dephasing rate of the electron spin of the NV center (1/T2★) as a signal. We show that for a range of mean ionic concentrations in the bulk of the electrolyte solution, the electric field fluctuations produced by the diffusional fluctuations in the local concentration of ions result in dephasing rates that can be inferred from free induction decay measurements. Moreover, we show that for a range of concentrations, the electric field generated at the position of the NV center can be used to estimate the concentration of ions.

  1. 2009 - Review on carbon-derived, solid-state, micro and nano sensors for electrochemical sensing applications [Crossref]
  2. 2014 - Nitrogen-Vacancy Centers in Diamond: Nanoscale Sensors for Physics and Biology [Crossref]
  3. 2017 - Probing photoinduced electron-transfer in graphene-dye hybrid materials for DSSC [Crossref]
  4. 2019 - A film-forming graphene/diketopyrrolopyrrole covalent hybrid with far-red optical features: Evidence of photo-stability [Crossref]
  5. 2013 - The nitrogen-vacancy color center in diamond [Crossref]
  6. 2014 - Electronic Properties and Metrology Applications of the Diamond NV− Center under Pressure [Crossref]
  7. 2013 - Nanometre-scale thermometry in a living cell [Crossref]
  8. 2011 - Electric-field sensing using single diamond spins [Crossref]
  9. 2014 - Magnetometry with nitrogen-vacancy defects in diamond [Crossref]
  10. 2008 - Nanoscale magnetic sensing with an individual electronic spin in diamond [Crossref]