Skip to content

Spin ensemble-based AC magnetometry using concatenated dynamical decoupling at low temperatures

MetadataDetails
Publication Date2017-12-14
JournalJournal of Optics
AuthorsD. Farfurnik, A. Jarmola, D. Budker, N. Bar-Gill
Citations11
AnalysisFull AI Review Included

Technical Documentation & Analysis: High-Fidelity AC Magnetometry using MPCVD Diamond

Section titled “Technical Documentation & Analysis: High-Fidelity AC Magnetometry using MPCVD Diamond”

This document analyzes the research paper “Spin ensemble-based AC magnetometry using concatenated dynamical decoupling at low temperatures” to highlight the critical role of high-purity, custom-engineered MPCVD diamond materials in achieving state-of-the-art quantum sensing performance.


This research validates the necessity of high-quality, isotopically pure Single Crystal Diamond (SCD) for advanced AC magnetometry using Nitrogen-Vacancy (NV) ensembles.

  • Material Requirement: Experiments relied on 99.99% isotopically enriched 12C CVD diamond to minimize the spin-bath environment and maximize coherence time (T₂).
  • Protocol Validation: The study compared standard (CPMG, XY8) and concatenated Dynamical Decoupling (DD) protocols for measuring AC fields between 10 kHz and 250 kHz.
  • Robustness for High Frequency: Concatenated XY8 protocols demonstrated superior robustness against microwave pulse imperfections, essential for high-frequency measurements requiring a large number of DD pulses (> 500).
  • Sensitivity Achievement: Achieved optimal magnetometric sensitivity of 9 nT/&sqrt;Hz at 10 kHz using the XY8 sequence.
  • Temperature Dependence: Cooling the diamond to 77 K significantly enhanced sensitivity only for low-frequency AC fields (around 10 kHz), where the experiment time approaches the longitudinal relaxation limit (T₁).
  • Engineering Implication: High-fidelity DD protocols require diamond substrates with extremely low intrinsic defects and precise control over NV concentration, a core capability of 6CCVD.

The following hard data points were extracted from the research paper, detailing the material properties and performance metrics achieved.

ParameterValueUnitContext
Diamond Isotopic Purity99.99%%12C enriched CVD sample
Nitrogen Concentration~2 x 1017cm-3Bulk impurity level
NV Concentration~4 x 1014cm-3Active sensing defects
Measurement Volume~25”m3Ensemble size
Static Magnetic Field (B₀)~300GApplied along NV symmetry axis
Room Temp Coherence Time (T₂ Hahn-Echo)~270”sStandard performance
Room Temp Longitudinal Relaxation (T₁)~5msLimits coherence time
Extended Coherence Time (T₂ XY8, n=48) @ 77 K~4msSignificant enhancement over RT (~1.2 ms)
AC Field Frequency Range (fAC)10 to 250kHzRange tested for magnetometry
Optimal Sensitivity (fAC = 10 kHz)9(1)nT/&sqrt;HzAchieved using XY8 sequence (n=32 pulses)
Optimal Sensitivity (fAC = 250 kHz)20(2)nT/&sqrt;HzAchieved using XY8 sequence (n=144 pulses)

The experiment relied on precise material engineering and sophisticated microwave control techniques, enabled by the high quality of the CVD diamond substrate.

  1. Material Growth: Use of high-purity, isotopically enriched 12C diamond grown via Chemical Vapor Deposition (CVD).
  2. NV Ensemble Preparation: The sample contained specific concentrations of nitrogen and NV centers, optimized for ensemble sensing.
  3. Optical Setup: Optical initialization and readout utilized a 532 nm laser pulse, measuring fluorescence contrast to determine the spin state.
  4. Static Field Application: A permanent magnet generated a static magnetic field (B₀ ~ 300 G) aligned with the NV symmetry axis to Zeeman-split the ms = ±1 spin sublevels.
  5. Microwave (MW) Control: MW π-pulses were delivered via a 70 ”m diameter wire, with spin-rotation axes controlled through In-phase/Quadrature (I/Q) modulation.
  6. Dynamical Decoupling (DD) Protocols: Comparison of CPMG, standard XY8, and recursively built concatenated XY8 sequences, synchronized precisely with the AC field frequency (fAC).
  7. Cryogenic Operation: Measurements were performed at Room Temperature (RT) and 77 K using a continuous-flow cryostat to study the effect of T₁ limitation reduction.

The successful replication and extension of this high-performance AC magnetometry research critically depends on access to highly controlled, custom-engineered diamond materials. 6CCVD is uniquely positioned to supply the necessary substrates and processing capabilities.

To replicate the high-coherence performance demonstrated in this paper, researchers require materials optimized for minimal decoherence.

  • Optical Grade Single Crystal Diamond (SCD): This is the ideal material. 6CCVD offers SCD with ultra-low nitrogen content (< 1 ppb) and precise isotopic enrichment (e.g., 99.99% 12C). This purity is essential for maximizing T₂ coherence times, which is the fundamental limit for DD protocols.
  • Custom NV Density Control: The paper utilized an NV concentration of ~4 x 1014 cm-3. 6CCVD provides custom nitrogen doping during growth or post-growth irradiation and annealing services to achieve specific, uniform NV densities, optimizing the signal-to-noise ratio for ensemble sensing.

The complexity of the DD protocols and the need for integrated MW delivery demand custom substrate engineering.

Research Requirement6CCVD Customization ServiceTechnical Benefit
Specific Dimensions/Geometry (e.g., small measurement volume, integration into cryostat)Custom Dimensions and Laser Cutting. We supply SCD plates up to 500 ”m thick and PCD wafers up to 125 mm, cut to precise, non-standard shapes.Ensures optimal placement and coupling efficiency within complex experimental setups (e.g., cryostats, MW coils).
Integrated MW Delivery (70 ”m wire, I/Q modulation)In-House Metalization Capabilities. We offer deposition of standard contacts including Au, Pt, Pd, Ti, W, and Cu directly onto the diamond surface.Enables the fabrication of high-fidelity on-chip microwave transmission lines and antennas necessary for robust concatenated DD pulse sequences.
Surface Quality (Minimizing scattering/loss)Ultra-Low Roughness Polishing. We guarantee surface roughness (Ra) < 1 nm for SCD and < 5 nm for inch-size PCD.Critical for minimizing optical losses during 532 nm laser excitation and fluorescence collection (C(n) efficiency).

6CCVD’s in-house PhD team specializes in the material science of quantum defects and sensing applications. We can assist researchers in:

  • Material Selection: Determining the optimal isotopic purity, crystal orientation, and NV creation method for specific AC magnetometry frequency ranges (low-frequency T₁ limited vs. high-frequency T₂ limited).
  • Process Optimization: Consulting on post-processing techniques (e.g., surface termination, annealing) to maximize the performance and stability of the NV ensemble.
  • Integration Support: Advising on the best metalization stack and geometry for integrating MW control structures onto the diamond substrate.

For custom specifications or material consultation, visit 6ccvd.com or contact our engineering team directly.

View Original Abstract

Ensembles of nitrogen-vacancy (NV) centers in diamond are widely used as AC magnetometers. While such measurements are usually performed using standard (XY) dynamical decoupling (DD) protocols at room temperature, we study the sensitivities achieved by utilizing various DD protocols, for measuring magnetic AC fields at frequencies in the 10-250 kHz range, at room temperature and 77 K. By performing measurements on an isotopically pure $^{12}$C sample, we find that the Carr-Purcell-Meiboom-Gill (CPMG) protocol, which is not robust against pulse imperfections, is less efficient for magnetometry than robust XY-based sequences. The concatenation of a standard XY-based protocol may enhance the sensitivities only for measuring high-frequency fields, for which many ($> 500$) DD pulses are necessary and the robustness against pulse imperfections is critical. Moreover, we show that cooling is effective only for measuring low-frequency fields (~10 kHz), for which the experiment time apporaches $T_1$ at a small number of applied DD pulses.