Skip to content

Efficient signal processing for time-resolved fluorescence detection of nitrogen-vacancy spins in diamond

MetadataDetails
Publication Date2016-01-13
JournalJournal of the Optical Society of America B
AuthorsAnchal Gupta, Luke Hacquebard, Lilian Childress
InstitutionsMcGill University
Citations69
AnalysisFull AI Review Included

Efficient Signal Processing for NV Spin Detection: Material Requirements and 6CCVD Solutions

Section titled “Efficient Signal Processing for NV Spin Detection: Material Requirements and 6CCVD Solutions”

This technical documentation analyzes the research paper “Efficient signal processing for time-resolved fluorescence detection of nitrogen-vacancy spins in diamond” (arXiv:1511.04407v1). The findings demonstrate that advanced signal processing techniques, specifically Maximum Likelihood Estimation (MLE), can significantly enhance the sensitivity of Nitrogen-Vacancy (NV) center quantum sensors, placing a premium on high-quality diamond substrates that enable high photon count rates and stable operation.


  • Core Achievement: Demonstrated a 7% increase in Signal-to-Noise Ratio (SNR) for room-temperature NV spin projection detection using Maximum Likelihood Estimation (MLE) signal processing.
  • Efficiency Gain: The SNR improvement is equivalent to a 14% increase in physical photon collection efficiency, achieved solely through data analysis of time-resolved fluorescence.
  • Methodology: The technique efficiently utilizes time-of-arrival information from photons, providing a more precise estimate of spin populations compared to traditional fixed-interval photon counting.
  • Optimal Operation: Analysis using a 5-level rate-equation model confirms that optimal SNR for NV spin detection occurs within a specific laser intensity range (1.5 - 2 * Isat).
  • Material Implication: The study highlights the need for high-purity Single Crystal Diamond (SCD) to mitigate power-dependent effects like dynamic charge state switching, which reduce SNR at high laser intensities.
  • Application: These improvements directly translate to enhanced sensitivity and speed for NV-based sensors used in magnetometry, thermometry, and quantum information science.

The following hard data points were extracted from the experimental results and modeling presented in the paper:

ParameterValueUnitContext
SNR Improvement (MLE vs. PC)7%Gain achieved by signal processing alone
Equivalent Photon Collection Efficiency Increase14%Physical equivalent of the SNR gain
Optimal Photon Counting Duration225nsCalculated optimal interval for standard counting
Excited State Lifetime (ms = 0, t0)12.9 ± 0.1nsMeasured lifetime for the bright spin state
Excited State Lifetime (ms = ±1, t1)6.3 ± 0.1nsMeasured lifetime for the dark spin state
Singlet State Lifetime (ts)139 - 145nsRange across different NV centers
Optimal Readout Laser Intensity1.5 - 2IsatIntensity range yielding maximum SNR
Initial Spin Polarization (Low Power)~90%Predicted polarization into ms = 0 state
Data Averaging Requirement3 * 107RepetitionsRequired for clear transient fluorescence traces
Detector Timing Resolution1nsUsed for time-tagged photon arrival events

The experiment focused on room-temperature NV spin detection, requiring precise optical and microwave control, coupled with high-speed time-resolved photon counting.

  1. Material Platform: Single NV centers (single defects) in high-purity diamond were studied at room temperature.
  2. Optical Excitation: A 532 nm green laser was used for optical initialization and readout, focused via a high Numerical Aperture (NA 1.35) oil immersion objective in a confocal microscope setup.
  3. Spin Manipulation: Microwave pulses were applied via a gold wire soldered across the diamond surface to drive the ms = 0 to ms = ±1 spin transition, enabling preparation of the two states for comparison.
  4. Data Acquisition: Time-resolved fluorescence was detected using a single photon counting module (70% quantum efficiency) with a 1 ns timing resolution. Photon arrival events were recorded by an FPGA card clocked at 120 MHz.
  5. Signal Processing Comparison: The experimental data was analyzed using two methods:
    • Standard Photon Counting (PC): Summing photons over an optimally chosen fixed interval (tmax).
    • Maximum Likelihood Estimation (MLE): Applying a weighting function based on time-of-arrival information to maximize the likelihood of estimating the spin projection Sz.
  6. Modeling: A 5-level rate-equation model was used to fit the time-dependent fluorescence traces and predict the SNR dependence on laser intensity, revealing discrepancies at high power attributed to dynamic charge state switching.

The successful replication and extension of this high-precision quantum sensing research depend critically on the quality, purity, and custom fabrication of the diamond substrate. 6CCVD provides the necessary MPCVD diamond materials and engineering services to meet these demanding specifications.

To replicate or extend this research, the highest quality diamond is required, specifically:

  • Optical Grade Single Crystal Diamond (SCD): Essential for high-fidelity NV center creation. Our SCD substrates offer low strain and high purity, minimizing background fluorescence and maximizing NV coherence times, which is critical for achieving high initial spin polarization (> 80%).
  • Low Nitrogen Concentration: Required to ensure isolated NV centers and minimize the effects of dynamic charge state switching observed at high laser intensities (as discussed in Section IV of the paper).

The integration of NV centers into practical sensing devices often requires precise geometry and integrated control elements. 6CCVD offers comprehensive customization:

Research Requirement / Challenge6CCVD Solution & CapabilityTechnical Advantage
Integrated Microwave ControlCustom Metalization ServicesWe offer in-house deposition of thin films (Ti/Pt/Au, Pd, W, Cu) for creating robust, high-frequency microwave striplines directly on the diamond surface, eliminating the need for cumbersome soldered gold wires.
High-NA Objective InterfaceUltra-Low Roughness PolishingSCD wafers are polished to an industry-leading surface roughness of Ra < 1 nm. This minimizes scattering losses and ensures optimal coupling efficiency for high Numerical Aperture (NA) objectives used in confocal microscopy.
Scaling and IntegrationCustom Dimensions and ThicknessWe provide SCD plates from 0.1 ”m to 500 ”m thick, and Polycrystalline Diamond (PCD) wafers up to 125 mm in diameter, allowing for the development of large-scale NV sensing arrays or integration with photonic devices [24, 25].
Substrate StabilityThick SubstratesWe supply diamond substrates up to 10 mm thick, providing robust thermal management and mechanical stability crucial for high-power laser operation where thermal effects [19] can degrade SNR.

6CCVD’s in-house PhD team specializes in MPCVD growth optimization for quantum applications. We can assist researchers in:

  • Material Selection: Consulting on the optimal nitrogen doping concentration and post-growth treatment (e.g., electron irradiation and annealing) to maximize the density and quality of NV- centers for similar magnetometry and thermometry projects.
  • Design for Integration: Providing technical guidance on integrating metalization patterns and optimizing diamond thickness for specific microwave or optical coupling requirements.
  • Global Logistics: Ensuring reliable, global shipping (DDU default, DDP available) for time-sensitive research projects.

For custom specifications or material consultation, visit 6ccvd.com or contact our engineering team directly.

View Original Abstract

Room-temperature fluorescence detection of the nitrogen-vacancy center electronic spin typically has low signal to noise, requiring long experiments to reveal an averaged signal. Here, we present a simple approach to analysis of time-resolved fluorescence data that permits an improvement in measurement precision through signal processing alone. Applying our technique to experimental data reveals an improvement in signal to noise, which is equivalent to a 14% increase in photon collection efficiency. We further explore the dependence of the signal-to-noise ratio on excitation power and analyze our results using a rate equation model. Our results provide a rubric for optimizing fluorescence spin detection, which has direct implications for improving precision of nitrogen-vacancy-based sensors. (C) 2016 Optical Society of America